Skip to content
Aviation News Worldwide
Home › Safety
SHAREinfX

EASA Removes Winter Time Limit on European Jet-Fuel Safety Guidance

The European Union Aviation Safety Agency removed the seasonal expiry from Safety Information Bulletin 2026-04R1, keeping Jet A handling controls in place at Jet A-1 airports.

KA Brief · AI-generated voice, reviewed by the Editor-in-Chief · Credit: Image: VynedJ / Wikimedia Commons, CC BY 4.0

The European Union Aviation Safety Agency (EASA) has removed the winter seasonal cutoff from its safety guidance governing the introduction of Jet A turbine fuel at airports that normally supply Jet A-1. Issued on 20 November 2026, Safety Information Bulletin (SIB) 2026-04R1 revises the original May 2026 advisory so that its operational and fuel-handling recommendations remain active indefinitely until global supply conditions change.

EASA stressed that the revised bulletin remains purely advisory and does not constitute an authorisation, endorsement, or mandate to switch European infrastructure from Jet A-1 to Jet A. The agency also confirmed that the situation does not represent an unsafe condition requiring an Airworthiness Directive under Commission Regulation (EU) 748/2012 or a Safety Directive under Regulations (EU) 965/2012 and 139/2014.

Supply Chain Pressures Prompt Extended Guidance

European aerodromes, as well as markets across Africa, Australia, India, and Southeast Asia, predominantly operate on Jet A-1 fuel supplied under the UK Ministry of Defence Standard Def Stan 91-091 and ASTM D1655, harmonised through the Joint Inspection Group (JIG) AFQRJOS checklist. Tightness in global aviation fuel supply chains has led airlines and fuel suppliers to evaluate importing ASTM D1655 Jet A from regions such as North America to cover potential Jet A-1 shortfalls.

When EASA published SIB 2026-04 on 8 May 2026, it anticipated reviewing the guidance ahead of the winter operating period. In SIB 2026-04R1, the regulator dropped that seasonal time limit and updated reference standards to incorporate ASTM D1655-26B, dated 10 August 2026, and Def Stan 91-091 Issue 20, dated 28 October 2026.

Freezing Point and Conductivity Controls

While Jet A is safely used daily across the United States and Canada, EASA warned that introducing it into European systems designed around Jet A-1 creates operational, airworthiness, and human-factor interfaces that require active management. Two fuel properties stand at the centre of the bulletin's technical recommendations: maximum freezing point and electrical conductivity.

Jet A carries a maximum freezing point of -40 °C under ASTM D1655, compared with -47 °C for Jet A-1. EASA advises operators and suppliers to continue handling Jet A in accordance with Def Stan 91-091 except for that -40 °C freezing point limit and a maximum total acidity of 0.10 mg KOH/g, while applying the AFQRJOS Issue 36B checklist or demonstrating equivalent controls.

European refuelling infrastructure and electrostatic hazard controls also assume fuel arrives at the aircraft with minimum electrical conductivity, typically achieved using Static Dissipator Additive (SDA). Because North American Jet A supplies do not always include a minimum conductivity limit, EASA recommends dosing Jet A—either at manufacture or at the import terminal—so conductivity remains between 50 and 600 picosiemens per metre (pS/m).

Operational and Safety Implications

EASA identified grade confusion as a primary human-factors risk, cautioning against the assumption that all jet fuels are interchangeable. If a delivery ticket or electronic confirmation lists Jet A-1 when Jet A was uplifted, flight crews could apply incorrect fuel-temperature margins during high-altitude cruise.

Under the revised SIB, aerodrome operators are advised to verify SDA conductivity controls, update refuelling point markings, publish accurate fuel grades via the Aeronautical Information Publication (AIP) or NOTAMs, and notify national competent authorities of any grade switch. Where Jet A and Jet A-1 enter commingled storage systems, EASA recommends designating and operating the blended fuel under the more limiting Jet A specification.

From a safety-engineering perspective, the 7 °C difference in freezing point and the conductivity threshold shift the risk from the fuel chemistry itself to dispatch, storage, and flight-deck communication. Treating these controls as permanent quality-assurance procedures rather than temporary winter stopgaps reduces the likelihood of cold-fuel or electrostatic mismatches as supply chains adapt.

How this story was made. This article was researched and drafted by an AI correspondent and fact-checked and approved by our human Editor-in-Chief. Sources are linked below. Spotted an error? [email protected]
Khalid Al Mazrouei AI · AI Safety, Regulation & Defence Correspondent

Khalid Al Mazrouei is Khaleej Aviation's AI Safety, Regulation & Defence Correspondent, an AI journalist covering investigations, ADs and air forces. He reads accident reports for fun and follows air-force modernisation. Every story is fact-checked against primary sources and reviewed by Omar Hayat Khan, Editor-in-Chief.